Introduction

May 26, 2017 by in NEUROSURGERY Comments Off on Introduction

© Springer International Publishing Switzerland 2016Paolo Cappabianca, Luigi Maria Cavallo, Oreste de Divitiis and Felice Esposito (eds.)Midline Skull Base Surgery10.1007/978-3-319-21533-4_1 1. Introduction Paolo Cappabianca1  , Marialaura Del Basso De Caro2 and Alessandro Villa1 (1) Division of Neurosurgery, Department of Neurosciences, Reproductive…

read more

Introduction

May 26, 2017 by in NEUROSURGERY Comments Off on Introduction

© Springer International Publishing Switzerland 2016Paolo Cappabianca, Luigi Maria Cavallo, Oreste de Divitiis and Felice Esposito (eds.)Midline Skull Base Surgery10.1007/978-3-319-21533-4_5 5. Introduction Paolo Cappabianca1  , Marialaura Del Basso De Caro2 and Arturo Brunetti3 (1) Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological…

read more

Wrist, Palm – Digits II, V

May 25, 2017 by in NEUROLOGY Comments Off on Wrist, Palm – Digits II, V

and Mario Di Napoli1 (1) Neurological Service, S. Camillo de’ Lellis General Hospital, Rieti, Italy   Original Settings Sensitivity was 20 μV/division, sweep speed was 2 ms/division, duration of pulse was 0.1–0.4…

read more

Wrist – Digit I, Wrist – Digit II, Wrist – Digit III, Wrist – Digit IV, Palm – Digit II, Palm – Digit III

May 25, 2017 by in NEUROLOGY Comments Off on Wrist – Digit I, Wrist – Digit II, Wrist – Digit III, Wrist – Digit IV, Palm – Digit II, Palm – Digit III

and Mario Di Napoli1 (1) Neurological Service, S. Camillo de’ Lellis General Hospital, Rieti, Italy   Original Settings Sensitivity was 20 μV/div (digit–wrist) and 50 μV/div (palm–wrist), low-frequency filter was 2 Hz,…

read more

Wrist – Digit I, Wrist – Digit II, Wrist – Digit IV

May 25, 2017 by in NEUROLOGY Comments Off on Wrist – Digit I, Wrist – Digit II, Wrist – Digit IV

and Mario Di Napoli1 (1) Neurological Service, S. Camillo de’ Lellis General Hospital, Rieti, Italy   Original Settings Sensitivity, low-frequency filter, high-frequency filter, sweep speed, duration of pulse, rate of pulse, and…

read more

Palm – Wrist; Wrist – Digit IV; Wrist – Digit I

May 25, 2017 by in NEUROLOGY Comments Off on Palm – Wrist; Wrist – Digit IV; Wrist – Digit I

and Mario Di Napoli1 (1) Neurological Service, S. Camillo de’ Lellis General Hospital, Rieti, Italy   Original Settings Sensitivity was 5–50 μV/division, low-frequency filter was 20 Hz, high-frequency filter was 2 kHz,…

read more